BLI 800 Animal Incinerator
Made In The United States of America

 

The B&L Cremation Systems, Inc. BLI 800 animal incinerator is a very popular size for small county or animal control facilities.  This system has a maximum load of 800 pounds and a destruction rate of 150 pounds per hour.

Specification U.S. Standard Metric System
Length: 125″ (133″ with cremation burner) 3.18 m (3.38 m with cremation burner)
Width: 64″ (78″ with control panel) 1.63 m (1.98 m with control panel)
Height: 72″ (84″ with afterburner) 1.83 m (2.13 m with afterburner)
Weight: 19,000 lb 8,618.26 Kg
Gas Pressure: Natural Gas: 7″ W.C.
Propane Gas: 11″ W.C.
Natural Gas: 1.74 kPa W.C.
Propane Gas: 2.74 kPa W.C.
Power RQMTS: 220 V, single phase, 30 AMPS
Incineration Rate: 150 lb/hr 68.04 Kg/hr
Body Weight Capability: 800 lb 362.87 Kg
Stack Height From Grade: minimum 15′ 4.57 m
Stack Sections: 24″ O.D. 609.60 mm O.D.
Refractory Insulation: 4.50″ firebrick walls
cast able refractory lining
(hearth and ceiling)
3″ 1900 – board insulation
0.11 m firebrick walls
cast able refractory lining
(hearth and ceiling)
0.08 m 1900 – board insulation
Chamber Dimensions: Length: 65″
Width: 40″
Height: 36″
54 ft³
Length: 1.65 m
Width: 1.02 m
Height: 0.91 m
1.53 m³
Burner Output:
  • Maximum Input Rating: 1,800,000 BTU’s per hour
  • Afterburner Maximum: 1,000,000 BTU’s per hour
  • Modulation Minimum: 100,000 BTU’s per hour
  • Cremation Burner: 800,000 BTU’s per hour
  • Maximum Input Rating: 1,899,100.08 KJ per hour
  • Afterburner Maximum: 1,055,055.60 KJ per hour
  • Modulation Minimum: 105,505.56 KJ per hour
  • Cremation Burner: 844,044.48 KJ per hour
Air RQMTS: Outside air inlet louvers in the room located at or below burner height, capable of passing 2,500 ft³ per minute of free air. Outside air inlet louvers in the room located at or below burner height, capable of passing 1.18 m³ per second of free air.

Features of the BLI 800 Animal Incinerator – Further information on fuel, oil, and specifications will be given upon request


FULLY AUTOMATIC CONTROL SEQUENCEOperation is made simple by the fully automatic control sequence.  A microprocessor temperature controller, with a digital readout, ensures optimum control while providing the lowest fuel consumption.  Visual verification of each stage is provided on the control panel.  Operator override is achieved by a turn of a switch for semi-manual control.
MULTI-CHAMBER AIR CONTROLLED DESIGNThe entire combustion process is completed within the air controlled chambers, eliminating burning in the stack, allowing for 24 hour operation, and providing for greater fuel efficiency over excess air designs.
POLLUTION MONITORING & CONTROL SYSTEMThis system constantly monitors the stack gases to prevent visible emissions. Integrated with the automatic system, this feature enables the unit to make all necessary adjustments automatically.
REFRACTORY LINED STACKA three inch insulating liner is provided as a safety feature.  While gases seldom exceed 1,000°F, the liner reduces heat penetration under every condition, preventing the possibility of fire.  A ten year warranty is offered on the stack liner.
LOW NOISEThe secondary combustion blower has been manufactured and installed to allow for low noise operation.