ul-ce-icon
BLP 1000 M10 Side 2
Made In The United States Of America

 

The B&L Cremation Systems, Inc. BLP 1000 M10 animal crematory is designed for large veterinarian facilities.  It is used for multiple cremation or a maximum load size of 1000 pounds.

Download Installation Manual

This design allows for multiple private cremations without co-mingling any remains; up to ten private cremations without any cremation pans required.  Still just as fuel efficient due to the “Hot Hearth” Design, this machine excels with the technology we continue to use today.

The primary chamber is divided into ten sections, openings vary from 41.5″ to 22″ x 19″.  All chambers are loaded through a counterweighted loading door, located on each side of the crematory.

*Custom designs are available

BLP 1000 M10 Multiple Pet Cremation Chambers
Specification U.S. Standard Metric System
Length: 281″ (295″ with Control Panel) 7.137 m (7.493 m with Control Panel)
Width: 101″ 2.565 m
Height: 90″ (96″ with Doorcap) 2.286 m (2.438 m with Doorcap)
Weight: 59,000 lbs 26,761.9 kg
Door Opening: 43.5″ – 20″ Width x 19″ Height 1.1049m – 0.508m Width x 0.4826m Height
Gas Pressure: Natural Gas: 7″ W.C.
Propane Gas: 11″ W.C.
Natural Gas: 1.74 kPa W.C.
Propane Gas: 2.74 kPa W.C.
Power Requirements: 220 V, Single Phase, 60 Cycle, 50 AMPS
110 V, Single Phase, 60 Cycle, 20 AMPS
Body Weight Capability: 1,000 lbs 4553.59 kg
Cremation Rate: 250 lbs/hr 113.40 kg/hr
Stack Height From Grade: Minimum 18′ 5.49 m
Stack Sections: 36″ O.D. 914.4 mm O.D.
Chamber Dimensions: Varies from 52.5″ to 29″ Length x 34.5 Width x 28″ Length Varies from 1.33m to 0.736m Length x 0.645 Width x 0.711 Height
Burner Output: Afterburner Maximum: 1,000,000 BTU per Hour
Cremation Burner: 750,000 BTU per Hour
Maximum Input Rating: 5,000,000 BTU per Hour
Modulation Minimum: 100,000 BTU per Hour
Afterburner Maximum: 1,055,055.6 kJ per Hour
Cremation Burner: 791,291.70 kJ per Hour
Maximum Input Rating: 512,500 kJ per Hour
Modulation Minimum: 105,505.59 kJ per Hour
Air Requirements: Outside air inlet louvers in the room located
at or below burner height, capable of passing
2,500 ft³ per minute of free air.
Outside air inlet louvers in the room located
at or below burner height, capable of passing
1.18 m³ per minute of free air.

Features Of The BLP 1000 M10 Animal Crematory


CONTROL SYSTEM AND POLLUTION MONITORING – This system constantly monitors the stack gases to prevent visible emissions.  Integrated with the automatic system, this feature enables the unit to make all necessary adjustments automatically.

FULLY-AUTOMATIC CONTROL SEQUENCE – Operation is made simple by the fully-automatic control sequence.  A microprocessor temperature controller with a digital readout ensures optimum control while providing the lowest fuel consumption.  Visual verification of each stage is provided on the control panel.  Operator override is achieved by a turn of a switch for semi-manual control.

HOT HEARTH DESIGN – First introduced by B&L, this design allows for wasted afterburning heat to be recycled through the floor, eliminating fluid problems, lowering fuel consumption, and extending the hearth life.

LOW NOISE – The secondary combustion blower has been manufactured and installed to allow for low noise operation.

MULTI-CHAMBER AIR CONTROLLED DESIGN – The entire combustion process is completed within the air controlled chambers, allowing for 24 hour operation, eliminating burning in the stack, and providing for greater fuel efficiency over excess air designs.

REFRACTORY LINED STACK – A three inch insulating liner is provided as a safety feature.  While gases seldom exceed 1,000 degrees Farenheit, the liner reduces heat penetration under every condition, preventing the possibility of fire.  A ten year warranty is offered on the stack liner.