BLP 1500
ul-ce-icon
Made In The United States of America

The B&L Cremation Systems, Inc. BLP 1500 animal crematory is designed for large veterinarian facilities.  It is used for individual cremation or a maximum load size of 1,500 lbs.

Specification U.S. Standard Metric System
Length: 236″ 5.99 m
Width: 84″ (96″ with control panel) 2.13 m (2.44 m with control panel)
Height: 120″ (125″ with doorcap) 3.05 m (3.18 m with doorcap)
Weight: 50,000 lb 22,679.62 Kg
Door Opening: 54″ width x 36.50″ height 1,371.60 mm width x 927.10 mm height
Gas Pressure: Natural Gas: 7″ W.C.
Propane Gas: 11″ W.C.
Natural Gas: 1.74 kPa W.C.
Propane Gas: 2.74 kPa W.C.
Power Requirements: 220 V, single phase, 60 cycle, 30 AMPS &
110 V, single phase, 60 cycle, 10 AMPS
Body Weight Capability: 1,500 lb 680.39 Kg
Cremation Rate: 300 lb/hr 136.08 Kg/hr
Stack Height From Grade: minimum 18′ 5.49 m
Stack Sections: 30″ O.D. 762 mm O.D.
Chamber Dimensions: Length: 100″
Width: 54″
Height: 48″
180 ft³
Length: 2.54 m
Width: 1.37 m
Height: 1.22 m
5.10 m³
Burner Output: Maximum Input Rating: 5,000,000 BTU’s per hour Maximum Input Rating: 5,275,279.25 KJ per hour
Air Requirements: Outside air inlet louvers in the room located at or below burner height, capable of passing 2,500 ft³ per minute of free air. Outside air inlet louvers in the room located at or below burner height, capable of passing 1.18 m³ per second of free air.

Features of the BLP 1500 Animal Crematory


FULLY AUTOMATIC CONTROL SEQUENCE – Operation is made simple by the fully automatic control sequence.  A microprocessor temperature controller, with a digital readout, ensures optimum control while providing the lowest fuel consumption.  Visual verification of each stage is provided on the control panel.  Operator override is achieved by a turn of a switch for semi-manual control.
HOT HEARTH DESIGN – First introduced by B&L, this design allows for wasted afterburning heat to be recycled through the floor, eliminating fluid problems, lowering fuel consumption, and extending the hearth life.
MULTI-CHAMBER AIR CONTROLLED DESIGN – The entire combustion process is completed within the air controlled chambers, eliminating burning in the stack, allowing for 24 hour operation, and providing for greater fuel efficiency over excess air designs.
POLLUTION MONITORING & CONTROL SYSTEM – This system constantly monitors the stack gases to prevent visible emissions. Integrated with the automatic system, this feature enables the unit to make all necessary adjustments automatically.
REFRACTORY LINED STACK – A three inch insulating liner is provided as a safety feature.  While gases seldom exceed 1,000°F, the liner reduces heat penetration under every condition, preventing the possibility of fire.  A ten year warranty is offered on the stack liner.
LOW NOISE – The secondary combustion blower has been manufactured and installed to allow for low noise operation.